■ Features
▶ High rigidity & Compact size
- Analyzing static stress
- Optimizing space usage
- Same performance with smaller width and length
▶ Standard specifications with various combinations.
▶ Offering ease-of-design through standardization table
▶ Noise optimization design (low-noise & low-frequency)
▶ Standard options of a Power-lock and semi-transparent inspection windows
for the L/R parallel type
▶ Using the same mounting hole, either fixing from below of the installation base
or securing from bottom inside of the robot base is all possible.
▶ Easy maintenance
■ Specifications
Input Motor (W) | 400 | ||||
LM Guide | No. 20 (2Rail 4Block) | ||||
Ball Screw size | Ø15 | ||||
Ball Screw lead (mm) | 05 | 10 | 20 | 30 | |
Repeatability (mm) | ±0.02 | ±0.02 | ±0.02 | ±0.02 | |
Maximum load capacity (kgf) | Horizontal | 80 | 70 | 50 | 20 |
Vertical | 50 | 33 | 16 | 8 |
Model | Strocke(mm) | Payload(kgf) | DWG | STP |
---|---|---|---|---|
URS 140-S | 50 - 1300 | 70(H), 33(V) | ||
URS 140-R | 50 - 1300 | 70(H), 33(V) | ||
URS 140-L | 50 - 1,300 | 70(H), 33(V) | ||
URS 140-B | 200 - 1,300 | 70(H), 33(V) |